Design Pressure (DP) Structural Certification.

What is Design Pressure (DP) Rating?

Design Pressure Rating is a term used to identify the structural capacity of a door system. Essentially Design Pressure represents the wind load the door system can withstand.

Read More

Structural Performance Label.

What does it mean?

A certified Structural Performance Label provides Design Pressure information for the building code inspector. The manufacturer has third party independent certification that proves the designated design pressure the door system performs to.

Reeb Certified Configurations

Which Reeb configurations qualify?

Reeb Millwork - Qualified Design Pressure Certified Structural Performance Configurations.

 

Depending on door configurations, DP47 or DP50 structural design certification labels will be applied to door units.

External Resources

Learn more about DP Rating?

“ We have testing units that duplicate hurricane winds and other conditions. ”

“ The DP rating is a measure of the level of wind force a door system can withstand without failing or cracking. ”

Design Pressure is a term used to identify the structural capacity of a door system. ”

What is Design Pressure Rating?

 

01. What does a Certified Structural Performance Label mean?

Design Pressure is a term used to identify the structural capacity of a door system. Essentially Design Pressure represents the wind load the door system can withstand.

 

02. What are the requirements for doors to qualify?

  • The Building Code requires hinged exterior doors to be tested to ASTM E330 for design pressure ratings and in the wind borne debris region the glazing in the door to be tested to ASTM E1886/1996 for impact and cycling.

  • Testing fenestration to ASTM E1886/1996 requires the complete door system be tested.

  • Door configurations are tested to a specified wind load pressure.

  • Modifications may be needed to components, assembly and installation procedures of the door configuration to achieve the specified DP ratings.

  • The tested door units with the necessary modification are then documented and are able to be certified to the achieved DP ratings.

 

03. Can door units carry a DP Rating if they have not been tested?

If an entire door unit is not tested, technically it does not carry DP rating.

 

What does a Certified Structural Performance Label mean?

 

  • A certified Structural Performance Label provides Design Pressure information for the building code inspector.

  • The manufacturer has third party independent certification that proves the designated design pressure the door system performs to.

  • The third party independent certification agency is in possession of the independent test reports support these performance claims.

 

Example of NAMI Certification Label shown below

 

NAMI Labels

 

Design Pressure is a term used to identify the structural capacity of a door system. Essentially Design Pressure represents the wind load the door system can withstand.

 

What does an Affidavit Structural Performance Label mean?

  • An Affidavit Structural Performance Label provides Design Pressure information for the building code inspector.

  • On an Affidavit Structural Performance Label the manufacturer is affirming or promising that the designated design pressure the door system will perform to.

  • The manufacturer is always the pre-hanger.

  • It is assumed that the manufacturer has some evidence to support these performance claims.

  • No independent testing or certification is necessarily required for the affidavit performance label.

  • There is no oversight of the performance claims.

 

Which modifications & reinforcements are required to achieve a DP Certification?

 

Construction difference for structural certification of Therma-Tru opaque and glazed continuous door systems.

 

Modifications needed to achieve DP certification requires #8 X 2-1/2" PFH wood screw located ½" from top and bottom of door (lock side only) pre-drill with 1/8" bit. This is performed by the pre-hanger during assembly.

 

Reeb Millwork - Qualified Design Pressure Certified Structural Performance Configurations.

 

  • Entry & Patio Systems

  • Both lock & deadbolt required

  • Center on center lock bore 12" for 8/0 units

  • Fiberglass & Steel Products

  • 6/8 & 8/0 Heights

  • Inswing & Outswing applications

  • Opaque & Glazed

  • With & Without Sidelites

  • With & Without Transoms (Patio Transoms Must Be Separately Framed Out)

  • Double Doors Use Coastal Astragal

  • Clear Lock Mullions w/Reinforcement Screws

  • Sidelite Units or Jamb Hinged Patio

  • Reinforcement Screws in Lock Stile See modification section

 

Depending on door configurations, a DP47 or DP50 structural design certification label will be applied to door units.

 

DP Structural Certification Configurations

 

Image Category Configuration Panel Type Height Swing Design Pressure DP Label Notes
Classic-CraftXOpaque6/8Inswing & Outswing9050
Classic-CraftXOpaque8/0Inswing & Outswing7550
Classic-CraftOX and XO jamb and mull hingedOpaque6/8Inswing & Outswing+50 -5550
Classic-CraftOX and XO jamb and mull hingedOpaque8/0Inswing & Outswing+60 -6550
Classic-CraftOXOOpaque6/8Inswing & Outswing+50 -5550
Classic-CraftOXOOpaque8/0Inswing & Outswing+60 -6550
Classic-CraftXXOpaque6/8Inswing & Outswing5550
Classic-CraftXXOpaque8/0Inswing & Outswing4747
Classic-CraftOX and XO jamb and mull hingedOpaque6/8Inswing & Outswing+55 -6050
Classic-CraftOX and XO jamb and mull hingedOpaque8/0Inswing & Outswing5550
Classic-CraftX/OOpaque6/8Inswing & Outswing+50 -5550
Classic-CraftX/OOpaque8/0Inswing & OutswingNonenone
Classic-CraftXO/O jamb and mull hingedOpaque6/8Inswing & Outswing+50 -5550
Classic-CraftXO/O jamb and mull hingedOpaque8/0Inswing & OutswingNonenone
Classic-CraftOXO/OOpaque6/8Inswing & Outswing+50 -5550
Classic-CraftOXO/OOpaque8/0Inswing & OutswingNonenone
Classic-CraftXGlazed6/8Inswing & Outswing5750
Classic-CraftXGlazed8/0Inswing & Outswing+60 -6550

(notes)

Classic-CraftOX and XO jamb and mull hingedGlazed6/8Inswing & Outswing5050
Classic-CraftOX and XO jamb and mull hingedGlazed8/0Inswing & Outswing+60 -6550

(notes)